Electric Vacuum Pump

Osaka Vacuum TG1100F Any Orientation Type Turbomolecular Turbo Pump Complete Set

Osaka Vacuum TG1100F Any Orientation Type Turbomolecular Turbo Pump Complete Set

Osaka Vacuum TG1100F Any Orientation Type Turbomolecular Turbo Pump Complete Set    Osaka Vacuum TG1100F Any Orientation Type Turbomolecular Turbo Pump Complete Set

Osaka Vacuum TG1100F Any Orientation Type Turbomolecular Turbo Pump Complete Set. Osaka Vacuum&###xA0;TG1100F&###xA0;Any Orientation Type Turbomolecular Turbo Pump - Complete Set Comes with: Turbo, Controller, Cables, Cooling, & Inlet Screen&##xA0. (Special Note: When ordering you will be asked if you need ISO or CF and Air Cooling or Water Cooling). Item Condition: New Complete Unit - Comes with: Turbo, Controller, Cables, Cooling, & Inlet Screen.

SKU: TBVM-TG1100F&###xA0; Location: Seiki seiko pump turbo controller control unit ac stp compressor turbomolecular molecular vacuum edwards boc. Osaka Vacuum&###xA0;TG1100F&###xA0;Any Orientation Type Turbomolecular Turbo Pump Complete Set.

(with protective screen)&###xA0;N2. Recommended backing vacuum pump&###xA0;(L/min). 1 : When using a backing vacuum pump of 500L/min.

2 : Differs according to the power supply model. 3 : The air cooling fan must be replaced if air-cooled. The ambient temperature range to ensure you reach the ultimate pressure is 10-23&##x2103.

The permissible ambient temperature is 10-32&###x2103; for air cooling type and 10-40&###x2103; for water cooling type. The maximum temperature for the cooling water which ensures the ultimate pressure is 30&###x2103; and the allowable temperature range for cooling water is 10-35&##x2103. Some service gases can deteriorate the lubrication grease and internal parts. 100-110 (&###xB1;10%) / 200-230 (&###xB1;10%).

Manual (Instruction, Serial communication instruction): 1 copy. Payments are expected in a timely manner. &###x200B;&###x200B;&###x200B;&###x200B;&###x200B;&###x200B;&##x200B. If you want to arrange your own transportation, we will provide you with accurate dimensions of the pallet(s).

These products are subject to export restrictions under U. Census and the&###xA0; Bureau of Industry and Security (BIS) &###xA0;regulate exports through the&###xA0; Export Administration Regulations (EAR). We DO NOT sell any items to any locations in Country Group E. Please be aware that we may require up to 30 Days to determine the products export classifications [Export Control Classification Number (ECCN)] and in the unlikely event that an export license is required, we would need an additional 30-90 Days for licensing. In order to comply with export control laws established by the US Department of Commerce and the US Department of State, we require a written statement defining the ultimate End User, the End Use of each product to be exported and the buyers' agreement to comply with the&###xA0; Export Administration Regulations (EAR).

30-DAY SATISFACTION GUARANTEE (EXPRESSLY WHERE NOTED). Customer confidence & satisfaction is our priority. Take pictures and send to us for reference for your claim. FOR PARTS OR NOT WORKING CONDITIONS (EXPRESSLY WHERE NOTED).

For parts or not working are for professional buyers and/or experts only. Our company respects your privacy.

We will never willfully disclose individually identifiable information about our customers to any third party, except in the limited circumstances permitted by this policy. Our company does not sell, rent, or loan any personally identifiable information regarding its customers to any third party. Any information you give us is held with the utmost care and security, and will not be used in ways to which you have not consented.

Compression ratio N2 1x108 H2 1x104 Ultimate pressure (Pa) <1x10-6 (Torr) <7.5x10-9 Max. Throughput12 (sccm) N2 330 860 Startup time2 (min) 7-9 5.5-7 Shutdown time2 (min) 27-32 12-15 Max. Backing pressure (Pa/Torr) 330/2.5 Recommended backing vacuum pump (L/min) &###x2267;250 Position Any orientation Weight (kg) VG, ISO-B/CF 28/27 Controller TC1104 TC11033 ---1 : When using a backing vacuum pump of 500L/min. --2 : Differs according to the power supply model. (standard:TC1104) ---3 : The air cooling fan must be replaced if air-cooled. (TG1100F-60) ---[Ambient temperature for use] ---The ambient temperature range to ensure you reach the ultimate pressure is 10-23&##x2103.--[Corresponding gases] ---Some service gases can deteriorate the lubrication grease and internal parts. Controller model TC1104 Input Voltage (ACV) 100-110 (&###xB1;10%) / 200-230 (&###xB1;10%) Input Frequency (Hz) 50/60 Input Phases Single Input Power (VA) 610 Rated Output Frequency (Hz) 560 Weight (kg) 2.7 Standard accessories ----Input connector: 1 ----Remote connector: 1 ----Serial communication connector: 1 ----Manual (Instruction, Serial communication instruction): 1 copy TMP TG1100F. The item "Osaka Vacuum TG1100F Any Orientation Type Turbomolecular Turbo Pump Complete Set" is in sale since Monday, November 17, 2014. This item is in the category "Business & Industrial\Hydraulics, Pneumatics & Pumps\Pumps & Pump Accessories\Vacuum Pumps\Other Vacuum Pumps".

The seller is "texassemicontech" and is located in Dallas, Texas. This item can be shipped worldwide.

  • Brand: Osaka Vacuum LTD.

  • Model: TG1100F
  • MPN: TG1100F
  • Application: Industrial / Lab
  • Power Source: Electric
  • Type: Diffusion / Vacuum
  • Country/Region of Manufacture: Japan
  • Inlet Flange: ISO 200 / CF 200
  • Pumping Speed, L/S Nitrogen: 1100
  • Pumping Speed, L/S Helium: 820
  • Pumping Speed, L/S Hydrogen: N/A
  • Ultimate Pressure (mbar): 10 - 9
  • Startup Time (min): 10
  • Rotational Speed (rpm): 33,600
  • Orientation: Any